Industrial Electronics

bridge calibration

Bridge Calibration: Fine-Tuning for Precise Measurements in Transducer Applications

Bridge circuits, particularly Wheatstone bridges, form the backbone of many transducer applications, allowing us to measure physical variables like pressure, strain, temperature, and displacement. These bridges rely on the principle of balancing resistances to produce an output signal proportional to the measured variable. However, achieving accurate and consistent measurements necessitates careful calibration of the bridge circuit. This process involves adjusting the bridge to eliminate any inherent offsets and establish a direct correspondence between the bridge output and the measured physical variable.

The Need for Bridge Calibration

Bridge circuits often exhibit slight imperfections or offsets, leading to inaccurate measurements. These offsets can arise from factors like:

  • Component Tolerance: Resistors used in the bridge circuit may have manufacturing tolerances, introducing small variations in resistance.
  • Temperature Effects: Temperature fluctuations can affect the resistance of bridge components, leading to shifts in the bridge output.
  • Non-Linearity in Transducers: Some transducers exhibit non-linear behavior, meaning their resistance change doesn't perfectly reflect the measured variable.

To address these challenges, a calibration process is essential. It involves two key aspects:

  1. Offset Elimination: Removing the inherent offset present in the bridge circuit, ensuring a zero output for zero input.
  2. Gain Adjustment: Establishing a specific relationship between the bridge output and the measured physical variable, enabling accurate readings across the full measurement range.

Bridge Calibration Techniques

The text you provided highlights two common techniques used for calibrating bridge circuits:

1. Offset Elimination:

  • Auxiliary Circuit: A parallel auxiliary circuit, including two resistors and a potentiometer, is connected across the bridge power supply diagonal. The potentiometer's tap is linked to the same bridge node as one end of the detector (usually a galvanometer or voltmeter).
  • Potentiometer Adjustment: By sliding the potentiometer tap, we can adjust the voltage at the bridge node, effectively compensating for the bridge offset. This ensures that the detector shows zero output when the measured variable is zero.

2. Gain Adjustment:

  • Series Circuit: A series auxiliary circuit, typically comprising a constant resistor and a variable resistor, is connected in series with the bridge power supply.
  • Voltage Control: Adjusting the variable resistor in this circuit allows us to change the voltage applied to the bridge. This step establishes the desired correspondence between the maximum detector deflection and the maximum value of the physical variable that the bridge resistors are designed to measure.

Summary:

Bridge calibration is crucial for achieving accurate measurements in various transducer applications. Through the use of auxiliary circuits and careful adjustment of components, we can eliminate offsets and establish a precise relationship between the bridge output and the measured physical variable. These techniques ensure reliable and accurate readings, empowering us to harness the power of bridge circuits for a wide range of scientific and engineering endeavors.


Test Your Knowledge

Quiz: Bridge Calibration

Instructions: Choose the best answer for each question.

1. What is the primary reason for calibrating bridge circuits?

a) To increase the sensitivity of the bridge. b) To reduce the cost of the bridge circuit. c) To ensure accurate and consistent measurements. d) To simplify the design of the bridge circuit.

Answer

c) To ensure accurate and consistent measurements.

2. Which of the following is NOT a factor that can lead to inaccuracies in bridge measurements?

a) Component tolerance b) Temperature fluctuations c) Non-linearity in transducers d) High input voltage

Answer

d) High input voltage

3. What is the purpose of "offset elimination" in bridge calibration?

a) To ensure the bridge output is zero when the measured variable is zero. b) To increase the sensitivity of the bridge. c) To reduce the effect of temperature fluctuations. d) To compensate for non-linearity in transducers.

Answer

a) To ensure the bridge output is zero when the measured variable is zero.

4. Which technique is used for offset elimination in bridge calibration?

a) Using a series auxiliary circuit with a variable resistor. b) Using a parallel auxiliary circuit with a potentiometer. c) Increasing the input voltage to the bridge. d) Using a digital signal processing unit.

Answer

b) Using a parallel auxiliary circuit with a potentiometer.

5. What is the main goal of "gain adjustment" in bridge calibration?

a) To compensate for non-linearity in transducers. b) To establish a specific relationship between the bridge output and the measured variable. c) To increase the power consumption of the bridge circuit. d) To reduce the effects of component tolerance.

Answer

b) To establish a specific relationship between the bridge output and the measured variable.

Exercise: Bridge Calibration Application

Scenario: You are tasked with calibrating a Wheatstone bridge used to measure strain in a structural component. The bridge has the following resistances:

  • R1 = 120 ohms
  • R2 = 120 ohms
  • R3 = 120 ohms
  • R4 = 120 ohms

You observe an offset voltage of 0.2 mV at zero strain. You also need to adjust the bridge to give a 10 mV output for a strain of 100 microstrain.

Task:

  1. Describe how you would use a potentiometer to eliminate the offset voltage.
  2. Explain how you would adjust the bridge to achieve the desired gain for a 10 mV output at 100 microstrain.

Exercise Correction

**1. Offset Elimination:** * **Connect a potentiometer:** Connect a potentiometer in parallel with the bridge power supply diagonal. The potentiometer tap should be linked to the same bridge node as one end of the detector (voltmeter). * **Adjust the potentiometer:** Slowly adjust the potentiometer tap until the detector reads zero volts when the strain is zero (no force applied to the structure). This will compensate for the inherent offset in the bridge. **2. Gain Adjustment:** * **Use a series resistor:** Connect a series resistor in series with the bridge power supply. * **Measure the initial output:** With the strain at 100 microstrain, measure the bridge output voltage. Let's say this output is 8 mV. * **Calculate the required gain:** You want a 10 mV output, so the gain needs to be adjusted by a factor of 10/8 = 1.25. * **Adjust the series resistor:** Adjust the value of the series resistor until the output voltage reaches 10 mV when the strain is 100 microstrain. The adjustment will increase the voltage applied to the bridge, effectively increasing the gain. **Important Note:** The specific values of the potentiometer and series resistor will depend on the bridge circuit configuration and the desired gain. You might need to experiment with different values to achieve the desired calibration.


Books

  • "Electronic Instrumentation and Measurement Techniques" by David A. Bell: This comprehensive text covers various measurement techniques, including bridge circuits and their calibration.
  • "Measurement Systems: Applications Design" by David R. Patranabis: Another well-regarded book that delves into bridge circuits, calibration methods, and application in measurement systems.
  • "Transducer Handbook" by Harry N. Norton: This book provides a deep dive into various types of transducers and their applications, including information on bridge calibration.

Articles

  • "Calibration of Strain Gauge Bridges" by K.J. Stout: This article, available on the "Strain Gauge Journal" website, provides a practical guide to calibrating strain gauge bridges.
  • "Wheatstone Bridge Calibration for Precise Measurement" by M.M. Radhika: This article, published in the "International Journal of Engineering and Technology" (IJET), explores the importance of calibration and discusses various methods for Wheatstone bridge calibration.

Online Resources

  • National Instruments Bridge Calibration Tutorial: National Instruments, a leading provider of measurement and automation systems, offers an online tutorial that explains different aspects of bridge calibration.
  • Omega Engineering Bridge Calibration Resources: Omega Engineering, a manufacturer of sensors and measurement equipment, has several articles and application notes on bridge circuits and their calibration.
  • Wikipedia Page on Wheatstone Bridge: While not specific to calibration, the Wikipedia page on Wheatstone bridges provides a good overview of the circuit operation and its various applications.

Search Tips

  • "Bridge calibration" + "type of transducer": This allows you to narrow your search to specific types of transducers, like "strain gauge," "pressure transducer," or "temperature sensor."
  • "Bridge calibration" + "technique": You can further refine your search by adding techniques, such as "potentiometer adjustment," "nulling," or "linearization."
  • "Bridge calibration" + "manufacturer name": Searching for a specific manufacturer like National Instruments, Omega, or Honeywell will often lead to their technical documentation or application notes on bridge calibration.

Techniques

Similar Terms
Industrial ElectronicsComputer ArchitectureElectromagnetismIndustry Regulations & Standards

Comments


No Comments
POST COMMENT
captcha
Back